1. pl
15 November 2023

Research of slab-column connections in an emergency condition caused by a punching shear. Connections reinforced according to Model Code 2010.

HOME PAGE   -   PUBLICATIONS   -   RESEARCH OF SLAB-COLUMN CONNECTIONS...

DOWNLOAD

Does designing a slab-column connection according to Model Code 2010 maintain the load capacity?

The publication concerns the third part of the research devoted to reinforcement integrating in slab-column connections. This time, the Model Code 2010 guidelines in this area were checked. The research took place at the Department of Building Structures of the Silesian University of Technology.

This bulletin refers to the Model Code 2010 design guidelines related to the use of reinforcement protecting the slab-column connection after punching shear, referred to as integrating reinforcement. Model Code 2010 requires that in the case of an internal connection, the reinforcement consists of at least four intersecting bars or eight bars not connected to each other, but appropriately anchored in the pole. In the case of an edge joint, it should be assumed that the number of appropriately anchored rods is six - Model Code 2010 does not directly indicate the solution for edge joints. In the case of an edge connection, the reinforcement anchoring perpendicular to the edge of the slab should be properly made.

Authors:

prof. dr hab. inż. Włodzimierz Starosolski

dr inż. Barbara Wieczorek

dr inż. Mirosław Wieczorek

Created by:  Platypus i Tako 